您好,欢迎光临本网站![请登录][注册会员]  
文件名称: VX-8R写频线驱动
  所属分类: Perl
  开发工具:
  文件大小: 3mb
  下载次数: 0
  上传时间: 2010-09-08
  提 供 者: BG6***
 详细说明: Installation and Configuration How to Install the Driver 1) Plug the Cable into a USB port. 2) The “Welcome to the Found New Hardware Wizard” or "Add New Hardware Wizard" (Win98) should appear. If it doesn’t appear, go to step 9. 3) Ensure the product driver CD (included with package) has been inserted in your CD-ROM drive. 4) Select the option: “Install the software automatically (Recommended).” or "Search for the best driver for your device" (Win98) 5) Press “Next”. Win 98 users should check CD-ROM drive. 6) Windows should find the “Prolific USB-to-Serial Comm Port” driver. Otherwise you should find the directory under your version of Windows under the "USB to RS232 1.1" directory on the CD-ROM. Windows 98 lists the device as "GM USB to Serial Bridge" 7) You will probably see a message indicating that the driver has not passed Windows Logo testing. Press “Continue Anyway.” This warning can be safely ignored. 8) Press “Finish” when prompted by Windows to complete the installation. *** If the “Found New Hardware Wizard” did not appear in step 2 *** 9) Open Device Manager by doing the following: a) Click on “Start” and then “Control Panel.” b) Switch to Classic View (if in Category View). c) Double click on “System.” d) Select the Hardware tab. e) Press the “Device Manager” button. 10) Under “Ports (COM & LPT),” look for a USB Device entry with a yellow exclamation point '!' by it. 11) Right click on the USB Device and select “Update Driver.” 12) This should bring up the “Welcome to the Hardware Update Wizard.” 13) Ensure the product driver CD (included with package) is inserted in your CD-ROM drive. 14) Select the option: “Install the software automatically (Recommended).” 15) Press “Next.” Continue from step 5 above. Looking for Drivers? How to Check the Driver Installation 1) Go to the Device Manager: Windows XP: Start -> Control Panel -> System -> Hardware -> Device Manager Windows 2000/2003: Start -> Settings -> Control Panel -> System -> Hardware -> Device Manager Windows 98/ME: Start -> Settings -> Control Panel -> System -> Device Manager 2) Click on the plus sign (+) next to "Ports." 3) If the device is installed properly, you will see "Prolific USB-to-Serial Comm Port. (COMx)" or "USB to Serial Port (COMx)" (Win98). Note that x is the number of the COM port (typically 1-8) assigned to the adapter. The driver is installed properly, but the device is not working First check to see that the Beagle Software application is set to the correct COM port number. To determine the COM port number assigned to the adapter, check the Device Manager (see above). It is also possible that the COM port number assigned is too high. Sometimes a device won't work with the USB-to-Serial adapter even though everything appears to have installed correctly because some computers will only scan a limited number of COM ports. For instance, it is possible that a computers has a limitation of scanning the first four COM ports. If the adapter is installed on COM5, a device with such a limitation will not work until the COM port is reassigned to COM1 - COM4. Windows XP, 2000, ME, and 98 include a function that allows you to reassign the COM port. Simply follow the instructions below: Windows XP port reassignment 1) Follow steps 1 and 2 in "How to Check the Driver Installation." 2) Right click on the "Prolific USB to Serial Port" and click on Properties 3) Click on the "Port Settings" tab. Click the "Advanced" button. 4) Pull down the scrollbar on the bottom, left side and select COM 1, 2, 3 or 4 (NOTE: Choose one that does not say "in use" next to it). Click "OK." 5) Click "OK" again. Notice that the device will show up as being on the same COM port that it was before (i.e., COM5), but will show up on the new port if you close the Device Manager and open it again. 6) Close the device manager. You may have to run the software that came with your device to make it rescan the COM ports. Windows 2000, ME, and 98SE port reassignment 1) Follow steps 1 and 2 in "How to Check the Driver Installation." 2) Right click on the "Prolific USB to Serial Port" and click on Properties 3) Click on the "Port Settings" tab. Click on the Resources tab. 4) Uncheck the box that says "Use automatic settings". 5) Select "Input/Output range". Click on "Change Settings". 6) Type "02E8-02EF" in the Value box. This value will change the port to COM 4. If COM 4 is in use, you must choose another port. The values for each port are: COM 1: 03F8-03FF COM 2: 02F8-02FF COM 3: 03E8-03EF COM 4: 02E8-02EF 7) After entering the value, click OK. Click OK again and click Yes when the "Creating a Forced Configuration" window appears. Click OK again. 8) Restart your computer. If you go into the device manager, you will see that the COM port has changed to the one you have selected. ...展开收缩
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 相关搜索: 驱动
 输入关键字,在本站1000多万海量源码库中尽情搜索: