您好,欢迎光临本网站![请登录][注册会员]  
文件名称: Fuji POD UG series(VARIABLE NAME COOPERATION FUNCTION).pdf
  所属分类: 其它
  开发工具:
  文件大小: 1mb
  下载次数: 0
  上传时间: 2019-10-15
  提 供 者: weixin_********
 详细说明:Fuji POD UG series(VARIABLE NAME COOPERATION FUNCTION)pdf,Fuji POD UG series(VARIABLE NAME COOPERATION FUNCTION)Matters Calling for Special Attention o The explanation in this manual about the variable name cooperation function applies to the Ver. 2.20(2.2.0.0)or newer UG00S-3WE (UGOOS-CW) o Use Ver. 1.2.0.0 or newer program-creation system software(D300win) for the MICREX-SX Series. When setting up ver. 2.2.0.0 or a previous version of D300win, enter a check for POd cooperated support]. (With Ver. 2. 2.1.0 and later versions, POD cooperation support is installed in the standard installation procedure For details, see"3. 1 Setting up D300win Record of revisions Printing date Reference no Revised Contents November. 1999 FEH363 1st Edition printed July, 2001 FEH363a 2nd Edition printed (Recorded as ver. 2.40) Compatible with D300Win Ver 2 Addition of data formats(date, tod DT. STRING formats Partial amendment December 2002 FEH363b 3rd Edition printed (Recorded as Ver. 3.00 D300win installation option changed Method for updating the variable name information during cooperation Partial amendmer Contents Preface Matters Calling for Special Attention Record of revisions 1 General ■■■■ 1-1 2. Connecting to MICREX-SX 2-1 3. Precautions Relating to D300win ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ 3-1 31 Setting up D300wn.……………………………………………………………………3-1 32 What variables can be cooperated?……………3-2 321 Type of variable.…………………3-2 322 AT setting… 4. How to Develop a screen with the Cooperation Function 4-1 4.1 Cooperating with a D300win project n4-2 4.11 Setting the project name……………s……………s……………………………42 4.1.2 Using the memories defined by d300win ..aan ■■■■■■■a■■■ 45 4.1.3 Defining a new memory from POD a4-8 4.2 Cooperating with a portable file aaaaaamaaaaaaaama 4-13 4.2.1 Setting the project name aaa.a ■■■■■■■ 4-13 4.22 Precautions on cooperating with a portable file,,…………………,………4-15 5. Developing a Screen without Cooperation 5-1 51 Setting the project name……5-2 5.2 Importing procedure…………………5 53 Exporting procedure……………………577 5.4 Developing a screen with the unit Pod editor only aaaaaa. 5-10 6. Data Type 6-1 61 BooL type.……s…s……ss……s…s…ss…s…s…6-1 62INT/ DINT type…… ■■■■■■■ ng6-1 6.3 UINT/UDINT type 6-3 64WoRD/ DWORD type…………………….6-4 65 Derived data type………………………6-5 651" Array"… 6-6 6.5.sTructured 7 6.5.3Array of Array 6-8 65.4“ Structured of Array"·………,,,…………… ■■■■■■■■■■■■■■■■■■■■■■■■■■ 6-11 655 Array of Structured",………………………6-13 6.5. 6Structured of structured 6-15 66 TIME type…………,…,…,…,,…………,…,,…………s……………,;6-17 6.7 ReaL type aas 6-18 68DATE, TOD and dt types…,,… n6-20 69 STRING type,,… 6-21 7. Variable Name Cooperation Function of PoD Editor 71 Variable name list… 7 711 Content of the list window 7-2 712 Changing the mode of the variable name list display……,,……,………7 7.1.3 Copying, moving and deleting a variable name.aaam. 714 Variable name replace and find functions………………………………7-6 715 Batch change of configurations, resources and worksheets………7-7 7.1.6 Comparison of variables 7-8 7.1。7 Cooperation option…………………s……s……s…………s…s…s……………s…s…………ss·7-9 7.2 Screen data transfer ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ -10 72.1 Download.………7-10 722 Upload,,aa,,,,,,,,,,7-12 72.3 Precautions on online editing…,,……… n7-13 8. Precautions on Using the Variable Name Cooperation Function . 8.1 Memory display eseseesseesssesssssssssessssssssasss8-1 8.2 Memory increment…………82 83 Memory batch change,……,…,8- 8. 4 Screen data filles wm8-6 8.5 Precautions on using the simulator 8-7 8.6 Compati bility of POD screen data between new and old versions .. 8-8 8.7 Combination with d300win versions w8-9 8.7.1 D300win projects 89 87.2 Portable file 8-9 Genera General With conventional PLCs, memory area is specified by alphabetic characters for area followed by a number for the memory address As a result, PODs have also employed this method to specify areas of PLC internal memory. But the micrex-sX series uses "label (variable) programming,, which describes the address part by using what we can imagine as a conventional comment When connected to an Sx, the pod editor uses a similar method for specifying the memory areas used for communications between applications, for the program creation tool for SX (D300win) and for the screen development editor for POD(UG00S-3WE (CW) Using common"variable names "increases the efficiency of PlC programming and POD screen development VAriable Name] Dialog for POD Editor Variable Name Variable Name ElementI Name: Sw 01 Same“ variable names” are used fc AT:比03 LP 04 development D01 PD_03 POD 04 POD 05 Dialog for Specifying a variable Name for D300win variable list of Re esource C_s×Rs32 Iype:F Variable:5w.01 Same“ variable names” are used Scope: C f or programming or screen Local varial development ADDERVIPOD 0 SW 01 SW 03 1-1 Genera Besides directly cooperating the POd editor with D300win, there is another method for creating programs or developing screens, i.e. using exported or imported intermediate files(portable files). The relation between these methods is shown below UGOOS-3WE D300win UGO0S-CW (1)Cooperation Global Worksheet (4)Export (Portable file) (5)Import Global Worksheet (6)Export ■■■■国 B lc (1)When cooperated During direct cooperation with D300win((1)in the above figure), at the moment new"variable names "are defined by the POD editor, their content is reflected at D300win To enable this method d300win needs to be activated in advance (both the D300win and the POd editor must be installed in the same personal computer During cooperation with a" portable file((2)in the above figure), at the moment newvariable names "are defined by the POd editor, their content is reflected in the portable file. When the variables are to be used also by d300win, D300win must import them from the "portable file With this method screens can be developed even when D300win is not activated (2 )When not cooperated During non-cooperation, variable names"are imported first from D300win or the portable file"(3)and(5)in the above figure) and then a screen is developed When"variable names"defined by the POd editor are to be used by d300win they need to be exported from the POd editor( (4)and(6)in the above figure) It is also possible to develop a screen without using(cooperating )variable names' defined by d300win at all If the operating speed of the editor becomes too slow in the cooperated state, use ne import/export function without cooperation Import/export, marked* in the figure above, is operated from D300win 1-2 Connecting to MiCReX-Sx Connecting to MICREX-SX The following methods can be used for connecting to MICREX-SX Connecting method POD editor setting Model of communications unit POD Side PLC Side Direct connection to SⅩ-BUS Fuji MICREX-SX(SX-BUS)UG03l-S, UG021-S Via t-LINK *1 Fuji MICREX-SX(T-LINK) UG03I-T, UG021-T NPlL-TL1 Via oPCn-1*1 Fuji MICREX-SX(OPCN-1)UG03l-, UGo21-J NPlL-JP Via Rs-232C/485 Fuji MICREX-SX Series NP1L-RS 1/2/4 Direct connection to Fuji MICREX-SX CPU loader port FL-Net General-purpose FL-Net UG03|E(E2) NP1L-FL1(FL2 When connected via T-link or OPCN-1, high-Speed 1O communication is possible. For the setting for 1/0 communication, see the manuals " UG Series (FEH356)and"UG Series (FEH358) 2 a dedicated cable is required for direct connection to the loader port See the manual UG30/20 Series "(FEH377, 352) 3 Only common memory communications are possible with an FL-Net connection which means that the variable name cooperation function cannot be used See the manual eSUG30/20 Series (FEH367) With the UG400/210 Series, only connection via OPCN-I is possible When using this series, be sure to select a product with an oPcn-l N interface and use NPlL-JPI at the plc 2-1 Precautions Re lating to d300Win Precautions Relating to D300win Be sure to use ver. 1.2.0.0 or a newer version of d300win 3卫 3.1 Setting up D300win When installing D300win Ver 2.2.0.0 or an earlier version, you must select [Custom] in the [setup Type] dialog, and then check the [Pod cooperated support] box when the [Select Components] dialog is displayed D300winSe etud Type to install the compn dooss Descr pion C Compact Progan wil be instaled with minimum required -pons amoy choose the options you wont to ins dl Recommended lot advenced Space Requred 59135K k Unless the"POD cooperated support "function is installed, portable files cannot be imported/exported from/into D300win.(Neither the [Import Labels] nor the [export Labels] command is displayed in the [extras] menu for D300win Extras Help Pagelayout Editor File Divide/Merge SX Control Utility Backup Utility Easy operation menu Import labels Export labels Memory Card Utility With D300win Ver 2.2. 1.0 and later versions the "Pod cooperated support "function is installed in the standard installation 3-1
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: