您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 酷马Q7000-IP英文版说明书.pdf
  所属分类: 其它
  开发工具:
  文件大小: 2mb
  下载次数: 0
  上传时间: 2019-10-13
  提 供 者: weixin_********
 详细说明:酷马Q7000-IP英文版说明书pdf,酷马Q7000-IP英文版说明书9 Parameters instructio 9.1 Initial setting 9.2 Parameters of Function for application 35 9.3 Adjust With Parameter 9.4 Parameters of Instruction 9.5 Parameters of motor 9.6 Parameters of Interface Card 42 9.7 Parameters of Exterior terminals 9. 8 Parameters of Protection 9.9 Parameters of Manipulator. 9.10 Parameterms Relative to elevators 10 Dedicated Functions for elevators 10.1 Requirements and Functions of Driving Elevator 57 10.2 Running Sequence Example 10.3 S Word Curve running 10.4 Starting Torque Compensation 10.4.1 Common Operation 10.4.aDjustment Method 60 Appendix 1Parameter table…… Appendix 2 Exception Display and Disposal for Self-learning of PG Original Pulse. 65 Appendix 3 Boundary Dimension 66 Appendix sTandard Specification 1 Product introduction Thank you for purchasing Q-7000-IP frequency converters. In order to enable users to make the most of this frequency converter and ensure users' safety, please read this operation and service manual carefully. When any problem beyond this manual is found during using, please contact local sales agency or our technicians of engineering department. Our professional technicians delight in service Please continue to use this product Use Directions] Frequency converters belong to electrical and electronic products. For your safety, "Danger"and Caution"items prompt you to take safe precautions when moving. installing, operating and inspecting frequency converters Danger: After powering off and before charge indicator light going out, please dont touch circuit board and parts and components Please don' t dismount and change inside connections or wiring and parts of frequency convert Not carry out wiring during powering on, not check parts and signals on circuit board during operation Make sure earth terminal of frequency converters is grounded correctly. For 220V, use the third grounding type, for 440V, use particular type Caution: Please don't perform any pressure test on inside parts and components of frequency converters, ince semiconductor parts are subject to damage resulted from high pressure Never connect output terminals(U, V, W) of frequency converters with input terminals(RIS\T of ac power supply Please not touch main circuit board, for parts and components on circuit board of a frequency converter are susceptible to static electricity and breakage. [Safe precautions for operation] Danger Not take off front cover of a frequency converter during powering on for keeping personnel from injury caused by electric shock stops, please not be close to the machine for keeping away from danger ically after its running hen automatic restart function is set. the motor will restart autom The function of stop switch is not valid until it is set. Since this switch is different with emer gency stop switch in usage, please keep attention on its usage Caution In order to prevent personnel from electric shock and injury, not touch heating elements such as The frequency converter is easy to run from low speed to high speed, please input allowable range of the motor and mechanics When using brake stoppers and so on, please keep attention to their relative setting about their verters are correctly adjusted at ex works, please don' t adjust them at will All frequency con Not check signals on circuit board of the frequency converter during runn Caution If frequency converters are damaged or lack of parts and components, never install them There is danger in injury 2 Product Inspection 2.1 Check items Items to be verified Check method Is there any difference with ordered product? Please check style of name plate on lateral side of EL-700-P Is there any damage? Check whole appearance and whether any damage Is there any loose condition on fasteners such as If necessary, check them with a screw driver. screws etc 2.2 Items on name plate Internal standard produ - MODEL: Q-7000-IP-1144 (AC440V/H15HP) Input source SOURCE: 3PHAC440V50/60HZ OUTPUT: 3PH AC0-440V11KW27A QmaeLectrIc(sHangHai)co.Ltdwww.chqma.com 3 Installation Wiring 3.1 USe Environment Installation environment of a frequency converter has direct effects on its normal use and service life so its installation environment must conform to the following Environment Temperature: +10-45C /+14-113F, for open style inside board Avoid rainwater and damp environment Keep from direct exposure in sunshine, oil fog and salty corrosion, corrosive fluid and firedamp cotton wool and metal chip invasion. Keep away from radioactive and inflammable substances Keep from electromagnetic interference(welding machine and dynamic machine) Keep from vibration, if unable to avoid, please install absorbing pad to reduce vibration. For sev eral frequency converters, please install them inside the control panel Please take attention to positioning for heat dissipation. In addition, please add a fan for heat dissi pation to make sure that environment temperature is below 45C. When installation, please make he front face frontward for heat dissipation Installation space must comply with specifications (If the frequency converter is installed inside the panel or ambient environment allows, take off its dust-resistant upper cover for heat dissipa tion and ventilation) Caution When moving, please support the bottom of the box. cover is held the body will drop to ot, causing injury possibly Please install it on noninflammable metal plate, otherwise fire may occur If several frequency converters are installed in the same control box, make sure that a cooling fan is placed and air temperature at inlet is below 45 C. Overheat may cause fire and other dangers 3.2 Installation Direction and Space For excellent cooling effect on EL-700-IP, make sure installation direction is vertical External dimensions and installation dimensions of the product refer to appendix3 "External Dimensions Air inlet temperature of the frequency converter must be controlled within the following range Installation inside the box:-10+45 C Charging part jumps over front face of the frequency converter Control box for installing the fre quency converter must have sufficient depth dimension to set aside space, and built-out iso- lation must be designed so that electric part can't be touched directly 3.3 Wiring Before wiring, make sure that input power is off. Electric shock and fire risk exists Wiring should be carried out by an electric engineer. Electric shock and fire risks exist fter Emergency stop loop is connected, be sure to check its action(wiring is within users'respon- sibility) Injury risk exists Caution Make sure power voltage on main DC loop is consistent with rate voltage of the frequency con verter Injury and fire risks exist Never carry out voltage test on the frequency converter, which may cause damage on semiconduc- tor etc Please follow wiring diagram to connect braking resistance. Fire risk exists Please use a torque-specified screw driver to fasten terminals. Fire risk exists 3.3. 1Method to connect main loop and control loop on EL-700-IP king Resistance Motor 人a Q7000-IP Reverse running/stop External anomal EF nomal undo ing (¥地 Multi-function inp LEyn Mut-octn nagy outlput External frc Mck-___------(Set output current at ex works. Common signal input terminal Connection terminal for shielded linc Powcr for frcqucncy 150r O--10V Main velocity comman d}篮丽m 0-+20mA Main vclocity oma Mutlti-function analoGy FIC set polar output (Set velocity-consisten enals 2器N ct polar output2( Set velocity-consistont Power for frcqucncy sctting +12 coma -ls(imA Common Multi-function open set polar output terminal Notel: Interval stranded wirc fote]: terminal platform +15, +12, .-15, 20mA CME FIY FIC+15 MET OY Y1 Y2 Yc -15 EA EB FC FWD REV EF RST MS1 MS2 JOG EX MY+ MOCMA+ RARE 6 3.3.2 Wiring on main lo anger Make sure to ground earth terminal (third grounding type) Injury and fire risks exist Caution Never connect power line to output terminals (U,v,w) Put voltage on output terminals will result in damage inside the frequency converters I Notice about wiring at input side on main loop 1) Setting a circuit breaker for wiring Make sure to connect a circuit breaker for wiring between supply power and junior main loop (R,s, T) 2)Setting a residual current circuit breaker If a residual current circuit breaker is connected on main loop, in order to prevent from wrong action, please use a residual current circuit breaker which adapts higher harmonics as a counter measure 3)Setting a electromagnetic contactor The frequency converter can be available if there is no electromagnetic contactor at main side. If a sequential controller is used to shut off main loop power instead of a circuit breaker for wiring, the electromagnetic contactor may be used. However, if the electromagnetic contactor on main side is used to stop the load forcibly, the regenerative brake won't work and free sliding stops Since the electromagnetic contactor on main side is locked, it is not allowed to run or stop the load. If a braking resistor element is used, use the hot protective relay contacts of the element to build up a time sequence making the electromagnetic contactor off, otherwise the braking resis tor may burn out when faults occur 4)Phase sequence of terminal block to be connected Phase sequence of input power has nothing with that(r, s, t)of terminal block, so any terminal can be connected 5)Setting a surge suppressor If inductive loads(electromagnetic contactor, relay, coil and breaker etc) are connected around o the frequency converter, please be sure to combine a surge suppressor Forbidden to set a phase-lead electrolytic capacitor In order to improve power factor and so on, if a phase-lead electrolytic capacitor and surge sup inserted into in de op of the frequency converter, the damage resulted from overhead caused by higher harmonic ingredients of the frequency con verter, furthermore, the frequency converter will failure due to current 7) Setting a noise filter at main side It is used to reduce higher harmonic noise from power line of the frequency converter Wiring at input side on main loop 1)Wiring between a frequency converter and a motor Connect its output terminals (Uvw) with motor's outlets (UVW). During operation, make yere that the motor is running positively under the positive running command. If the motor runs reverse order, choose and interchange two terminals among U.V.W. Never connect power input line to output terminals Never connect power input line to output terminals. If voltage is brought to output terminals, inner apparatus of the frequency converter will damage 3) Setting a low-voltage manual switch Even if the frequency converter is powered off, the motor continues to enable the load running, please insert a low-voltage manual switch into input side of the frequency converter. During maintenance and wiring troubleshooting, please keep the switch on 4) Never short and ground output terminals Never touch output terminals directly or make output lines touched with outer shell of the fre quency converter. Electric shock and short circuit risks exist. In addition, never short output 5) Never use a phase-lead electrolytic capacitor and noise filter Never connect any phase-lead electrolytic capacitor and LC/RC noise filter in output loop Con- nection with such components would make the frequency converter damaged, components burn 6) Never use a electromagnetic switch Never connect any electromagnetic switch and contactor to output loop. If the frequency con verter connects with the load during operation, it will result in over-current protection loop per forming false operation due to surge current 7)Setting a hot protective relay The frequency converter has overload protection function. If a hot protective relay is used 8)Installation of noise filter at output le (to choose motor protection as no motor protection) lease set the parameter Pl-01 equal o( Connecting a noise filter at output side of the frequency converter could reduce radio interfer ence and induced interference Induced interference: Electromagnetic induction makes signal line containing noise, resulting in alse operation of control device Radio interference: High-frequency electromagnetic waves generated by the frequency con- verter itself and power cables make the radio give out noise during receiving signals 2) Countermeasure on induced interference In addition to setting a noise filter as described above, all output lines are imported into a metal tube could be used to inhibit induction at output side. Furthermore, when distance from signal line is beyond 30cm, effects of induced interference reduce remarkably 10) Radio interference Both the frequency converter itself and output would generate induced interference, so both input and output sides have a noise filter, if the whole is screened with an iron box radio interference would reduce. Furthermore, connection distance between the frequency con- erter and motor should be as short as possible 3 Earth wiring ge sure to use the third grounding type for earth wiring Never share the same earth wire with welding machines and power plants. Used earth wire should have a little bigger diameter than that specified in technical basic of electrical equipments, and be as short as possible Under the condition of using several frequency converters, please give attention to never enabling earth wire formed a loop 4 Function of terminals on main loop The following list shows functions of main loop terminals in their mark order, please refer to cor rect target connectie Functions of main loop terminal Terminal Function R Input terminal of main supply Main DC Supply (dct positive vol Main DC Supply (dc-negatice voltage Connection point for braking resistance U Output terminals of the frequency converter E For (The third gr g type) RsTB1OB2ulvw Take example for 15HP and20HP INPUT OUTPUT 3.3.3Control Loop Wiring Method Functions of control loop terminals are showed in the following list. Please choose proper terminals 1)Description on control loop terminals Control Loop Terminal table Signal Name Description Signal level Mark FWD Positive running-stop Close" for positive running. " Open REV Reverse running-stop"Close "for reversal, Open"for stop EF External abnormal input"Close"for faults aRET Abnormal fault reset Close"for reset DC+24V 8mA MS1 Multi-velocity com- Closefor auxiliary frequency Isolated photoele cou ≌「MS2Muti- velocity com-Cose” to validate multi-veloc| terminals Imand 2 ity setting 2 (T-01-T1-06) JoG Inching command Close for inching BX External stop action "Close"for output stop of the fre- COM Common terminal +15 +15 power output +15V supply for analog command 15V20mA power outpu -15V supply for analog command V 20mA FIv Main velocity command -10V-+10V/-100%-+100% 10V~+10V(20KΩ) 0V~+10v/100% V-10V, (20KS 阵-20mA/100%-10V~+10V/-100%~+100% 4-20mA,(2502) a MFI Torque compensation -10V-+10V/-100%+100%Auxiliary analog input for startup 0V~+10V/100% 0V~+10V(20K92) OV Common terminal for Close"at the end of"Close"at the end of torque compen- Terminal capacity RC torque compensation sation elow ac250 1A Multi-function Below DC250 1A YI Null speed check output Close"under electrical level (22-01output terminals Open collector output at null speed (T2-01-T203) below+48V,50mA* 2 Consistent velocity Close” within±2 Hz of setting fre Check output YC Common output termi hal for YI and Y2 EA Fault output signal(lc EA-EB"closed"when faults occur. terminal) B-EC“open” when faults occur. Below AC250V 1A ault output Below DC30V 1A terminal) ec Fault output signal(lc terminal) MV+ Consistent frequency Multi-function analog 0-+10V max (T4-01,T4-02) MOC Common terminal MA+ For monitoring output IoV/rated torque of fre-Multi-functior (T4-04,T4-05) 2) Notice on control loop wiring Control loop wiring should separate from main loop wiring(R, S,T,Bl, e, B2, U,V,W)and other In order to prevent from interference and false operation, use shielded line to connect control loop Wiring length should be limited within 50m 3.3.wIring Inspection After wiring, be sure to check interactive connections. Never use singing function at this time Is there any wiring mistake? Do wire scraps and screws remain at electrical circuits? Do thread ends of terminals touch with other terminals?
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: