您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 施耐德变频器ATV21 Lonworks card用户手册(英文).pdf
  所属分类: 其它
  开发工具:
  文件大小: 1mb
  下载次数: 0
  上传时间: 2019-10-08
  提 供 者: weixin_********
 详细说明:施耐德变频器ATV21 Lonworks card用户手册(英文)pdf,施耐德变频器ATV21 Lonworks card用户手册(英文)Contents Important Information Before you begin Introduction Documentation structure Hardware setup Receipt 56789999 Hardware description Use of RS485 communication port Description of terminals 10 stalling the card in the drive Connecting to the bus Topology 12 Cable routing practices 13 Wiring the LONWORKS connector Configuration Drive parameters overriden by the LONWORKs network Configuration of the internal communication Configuration of the control 15 Control by the LoNWoRKs network 15 Control by terminals, monitoring by the LON WORKs network 16 Control by the LONWORKs network, switching setpoint to terminals by logic input Setpoint by the LoNWoRks network, switching commands to terminals by logic input Configuration of the lonworks fault 18 Diagnostics 20 Service LED 20 Troubleshooting 20 Functional profile 21 Objects supported 21 LONMARK Node Object profile LON MARK Variable Speed Motor Drive profile 22 Network variables and configuration properties 23 List of network variables and configuration properties Commands and setpoints 25 Drive Speed Setpoint (nviDrv SpeedStpt) 25 Drive Speed Setpoint Scaling(nviDrvSpeedScale 25 Default Value for nviDrvSpeedScale(nciDrvSpeedScale) 25 Frequency setpoint (nvilnvSetFreq Reset command(nviResetFault 6 Status and output velocity 28 Drive Speed Feedback(nvoDrv Speed) 28 Drive Velocity feedback(nvoDrv Feedback 28 Output frequency(nvolnvOutFreq) 28 Drive status(nyoStatusWord) 9 Alarms 3 Alarm code(nvoDrv Alarm) 31 Alarm status(nvoAlarmWord) 31 Measurements 32 Drive Output Current (nvoDrvCurnt) Drive Total Running Hours(nvoDrvRunHours) Energy consumption(nvoDrvEnergy Torque actual value(nvo Torque) 32 Monitoring of digital input 33 Monitoring of digital input F(nvoDigitalln1) 33 Monitoring of digital input R(nvo Digitalln2) Monitoring of analog inputs Monitoring of analog input viB(nvoAnalogIn2 Control of digital outputs 33 Control of relay FL (nviRelay 1) 33 Emergency Emergency command(nviEmergoverride) Emergency status(nvoEmerg Status) 34 176959210/2009 Contents Adjustment Maximum Motor Speed(nciMaxSpeed) 35 Minimum Motor Speed (nciMin Speed) 35 Nominal Motor Speed in RPM(nciNmISpeed) 36 Nominal Motor Frequency(nciNmlFreg 36 Minimum Ramp Up Time(nciRampUpTm) Minimum Ramp Down Time(nciRampDownTm) 37 Parameter access 38 nviParamCmd, nvoParamResp Identification Location Label (nciLocation) dentification(nvo Type Ver) Network management 41 Send Heartbeat Time(nciSndHrtBt) 41 Receive Heartbeat Time(nciRcvHrtBt 41 Minimum Send Time(nciMinOutTm) Power supply start waiting time(ncipwUpOutTm While every precaution has been taken in the preparation of this document, Schneider Electric SA assumes no liability for any omissions or errors it may contain, nor for any damages resulting from the application or use of the information herein The products described in this document may be changed or modified at any time, either from a technical point of view or in the way they are operated. Their description can in no way be considered contractual 176959210/2009 1. Important Information NOTICE Read these instructions carefully, and loak at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure A The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists, which will result in personnal if the instruction are not followed A This is the safety alert symbol. It is used to alert you to potential personal injury hazards. obey all safety messages that follow this symbol to avoid possible injury or death A DANGER DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death, serious injury, or equipment damage A WARNING Warninig indicates a potentially hazardous situation, which, if not avoided, can result in death, serious injury, or equipment damage A CAUTION CAUTION indicates a potentially hazardous situation, which, if not avoided, can result in injury or equipment damage PLEASE NOTE Electrical equipment should be serviced only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. This document is not intended as an instruction manual for untrained persons o 2005 Schneider Electric. All Rights Reserved 176959210/2009 2. Before you begin Read and understand these instructions before performing any procedure with this drive, in order to completely and correctly utilize excellent performance of this unit Besides this user manual, you will find in the chapter"Documentation structure"which manuals we advice you to read to develop software communicating with Altivar 21 If you need support, please contact our sales offices After reading this instruction manual, please keep it handy for future reference Read and understand these instructions before performing any procedure with this drive A DANGER HAZARDOUS VOLTAGE Read and understand the Installation Manual before installing or operating the Altivar 21 drive Installation, adjustment, repair, and maintenance must be performed by qualified personnel The user is responsible for compliance with all international and national electrical standards in force concerning protective grounding of all equipment Many parts of this variable speed drive, including the printed circuit cards, operate at the line voltage. DO NOT TOUCH. Use only electrically insulated tools DO NOT touch unshielded components or terminal strip screw connections with voltage present DO NOT short across terminals Pa and PC or across the dc bus capacitors Install and close all the covers before applyit lower or starting and stopping the drive Before servicing the variable speed drive Disconnect all power Place a"DO NOT TURN ON"label on the variable speed drive disconnect Lock the disconnect in the open position. Disconnect all power including external control power that may be present before servicing the drive. WAIT 15 MINUTES to allow the DC bus capacitors to discharge. Then follow the dc bus voltage measurement procedure given in the Installation Manual to verify that the DC voltage is less than 45 VDC. The drive LEDs are not accurate indicators of the absence of dc bus voltage Electric shock will result in death or serious injury A CAUTION DAMAGED EQUIPMENT Do not install or operate any drive that appears damaged Failure to follow this instruction can result in injury or equipment damage 176959210/2009 3. Introduction Thank you for purchasing the LONWORKs option card (VW3A21312)for Altivar 21 drive By installing this card into the Altivar 21, data communication can be made with a host computer or other device via LoNWoRks network The communication card has an open-style 3-pin connector for connection to the network. It supports free topology at 78 kbit/s Data exchanges give access to all Altivar 21 functions Control(start, sto Monitoring(status, current, voltage, thermal state.), Diagnostics(alarms The LonWoRks resource files( XIF.)that provide the network configuration tools(Lon Maker. with device information are available on theweBsitewww.schneider-electric.comandonthecdromdeliveredwitheachdrive The plug-in software tool that provides easy access to setting-up, testing and monitoring the ATV21 drive is also available on the Web site www.schneider-electric.comandonthecdromdeliveredwitheachdrive LONWORKS, LONMARK, Lon Maker, Neuron are trademarks of Echelon Corporation registered in the United States and other countries LONMARK and LoN MARK Logo are managed, granted, and used by LoNMARK International under a license granted by Echelon Corporation 176959210/2009 4 Documentation structure ■ LONWORKS ATV21 manua The present LONWORKS user manual describes connection to Lon Works network configuration of the communication-specific parameters via the HMI diagnostics networks variables You will also find important information in other Altivar 21 technical documents. They are available on the Web site www.schneider-electric.comandonthecdromdeliveredwitheachdrive ATV21 user manual This manual describes: How to assemble the drive How to connect the drive The functions and the parameters of the drive How to use the drive hmi If you use the Parameter access function of (nviParamCmd, nvoParamResp), will find in this manual the address and possible values of the parameters of the drive ■ Modbus atv21 manual This manual describes Connection to the bus or network Configuration of the cammunication-specific parameters Diagnostics Software setup, Modbus services supported If you use the Parameter access function of (nviParamCmd, nvoParamResp), will find in this manual the address and possible values of additional parameters not described in aTV21 user manual 176959210/2009 5. Hardware setup 5. 1. Receipt Check that the card reference printed on the label is the same as that on the delivery note corresponding to the purchase order Remove the option card from its packaging and check that it has not been damaged in transit The LONWORKs card is shipped together with the following accessories. On opening the packing case, check to see if the following accessories are contained or not 1 cabling label and 2 name plates (1 sheet 1 insulating sheet 3 neuron ID labels( barcode EAN128 5.2. Hardware description Service pin SW2 Selector switch SW1 Connector to drive Logic for f, r terminal (SINK/SOURCE) VIB function (VIB/PTC) Service LED n FR∨|BCCP24 Terminal board fixing screw hole (M3 screv NETA SHLDNETB G/E FLA FLB Flc RS485 communication port RJ45 Earth connection terminal LONWORKs network detachable terminal A DANGER Operate service pin only when a cover for the main circuit terminal is attached. Otherwise, it could lead to electric shocks Operate service pin using a non-conductive stick When it is operated with a conductive stick, it could lead to electric shock 5. 3. Use of RS485 communication port Serial communication(2-wire RS485 option can be used for Modbus, PC software or remote keypad One internal communication line is available either for the RS485 communication port or for the LoNWoRks port So, while RS485 communication is used(connected to the appropriate cable or interface) the lonWorks port is disabled 176959210/2009 5. Hardware setup 5. 4. Description of terminals Terminal Function Electrical specifications nternal circuits symbol NETA No polarity NETA NETB LONWORKs transmission data /reception data NETB( This terminal is not connected to any SHLD LONWORKS communication shield terminal other circuit of the card ground this SHLD terminal in a location separated from FT-×1 ne ground of power line G Spark G/E Grounding terminal Please connect to network ground gap Multifunctional programmable logic input P24 has forward rotation function in default setting ON forward rotation drive No voltage contact input F24 SOURCE OFF: slowdown and stop 24VDC. 5mA or less Multifunctional programmable contact input SINK/SOURCE can be selected with SW1 It has reverse rotation function in default setting 本水 FR ON: reverse rotation drive OFF: slowdown and stop Multifunction programmable analog input (0 to 60Hz frequency with 0 to 10VDC input. ng. 10VDC Vib It has speed set point function in the default setti PTC/ VIB In addition, this terminal can be used as PTC input by Internal impedance: 30kohm setting the parameters( F645 and F646)and sw1 Cc Control circuit equipotential terminal P2424 VDC power supply output 24VDC-50mA P24「 Multifunctional programmable relay contact outputs. 30VDC-05A FLa Default setting is set to detect the activation of the 250VAC-1A -B inverter protection function 日 FLC Contact across FLA-FLC is closed and FLB-FLC is 250VAC-05A opened during protection function operation (cosφ=04) LC A DANGER Do not change switch settings while power is on It may damage the product or lead to electric shocks and breakdown When setting the VIB function, set the parameter after configuring removed motor cables. The motor may suddenly start and that could result in injury 176959210/2009
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: