您好,欢迎光临本网站![请登录][注册会员]  
文件名称: DELTA_IA_ASDA-B2_UM_EN_20180509 英文版使用手冊.pdf
  所属分类: 制造
  开发工具:
  文件大小: 13mb
  下载次数: 0
  上传时间: 2019-07-08
  提 供 者: kenn*****
 详细说明:Thank you for purchasing ASDA-B2. This user manual provides the related information of ECMA series servo motors. This manual includes: Installation and inspection of servo drive and servo motor The configuration of servo drive Procedures of trial run Control functions and adjustment methods of sPrefa ASDA-B2 Do not touch the heat sink to avoid scald before connecting to the power and operation If you have any enquiry, please contact the distributors or Delta customer service center Safety Precautions ASDA-B2 series is the high resolution and open type servo drive. It should be installed in a shielded control box during operation. This servo drive uses precise feedback control and the digital signal processor with high-speed calculation function to control the current output which generated by IGBt so as to operate three-phase permanent magnet synchronous motors(PMSM) and to achieve precise positioning ASDA-B2 is applicable on industrial application and is suggested to be installed in the panel-board of the user manual (Servo drives, wire rod and motors all should be installed in the environment which complies with the minimum requirement of UL Level 1 or NEMA 250Type1.) Pay special attention to the following safety precautions anytime during inspection, installation, wiring, operation and examination The symbol of danger warning and stop represent: DANGEP It indicates the potential hazards. It is possible to cause severe injury or fatal w harm if not follow the instructions A It indicates the potential hazards. It is possible to cause minor injury or lead to WARNING Serious damage of the product or even malfunction if not follow the instructions It indicates the absolute prohibited activity. It is possible to damage the product or cannot be used due to malfunction if not follow the instructions Inspection Please follow the instruction when using servo drive and servo motor or it is DANGER possible to cause fire or malfunction Installation DANGER> It is prohibited to expose the product with the environment which containing water, corrosive gas, inflammable gas, etc. Or it is possible to cause electric shock or fire Revision May, 2018 ASDA-B2 Preface Wiring oAN Please connect the ground termina l to class- ground system(under 100 Q) Do not connect the three-phase source to the motor output terminal U, v and W. Or it is possible to cause personnel injury or fire Please tighten the screws of the power and motor output terminal. Or it is possible to cause fire Operation Before the operation, please change the parameter setting value according to the needs. If it is not adjusted to the correct setting value, it is possible to lead WARNING to malfunction of the machine or the operation might out of control Before the machine starts to operate, please be ensured the emergency stop can be activated anytime During the operation, it is prohibited to touch any rotating motor parts Or it is possible to cause personnel injury In order to prevent any accident, please separate the couplings and belts of the ⑤ DANGER machine and isolate them then conduct the initial trial run If users fail to operate the machine properly after the servo motor connects to the equipment, it would cause the damage of the equipment and lead to the personnel injury In order to prevent the danger, it is strongly recommended to check if the me can operate normally without load first. Then, operate the motor with loadrotor Do not touch the heat sink of the servo drive. Or it is possible to cause scald due to the high temperature Maintenance and Inspection It is prohibited to touch the internal parts of the servo drive and servo motor STOP Or it is possible to cause electric shock It is prohibited to disassemble the panel of the servo drive when turning on the power. Or it is possible to cause electric shock Do not touch the ground terminal within 10 minutes after turning off the power. Or the residual voltage may cause electric shock Do not disassemble the motor. Or it is possible to cause electric shock or personnel injury Do not change the wiring when the power is on Or it is possible to cause electric shock or personnel injury Only the qualified electrical and electronics professionals can install, wire and maintain the servo drive and servo motor Revision May, 2018 Prefa ASDA-B2 Main Circuit Wiring Do not put the power cable and the encoder cable in the same channel and bond them together. Please separate the power cable and the encoder WARNING cable for at least 30 centimeters(=11.8 inches )when wiring Please use stranded wires and multi-core shielded-pair wires for the encoder cables and encoder feedback cables. The maximum length of command input cable is 3 meters(=9. 84 feet) and the maximum length of feedback cable is 20 meters( 65. 62 feet) The high voltage might remain in the servo motor even when the power is off. Do not touch the power terminal temporally(at least 10 minutes) Please conduct the inspection not until the indicator light, CHARGE is off Do not turn the power on and off too often If continuous power on and off is STOP needed, please be ensured the interval is one minute at most Terminal Wiring of the Main Circuit When wiring, please disassemble the terminal socket from the servo drive One terminal of the terminal socket for one electric wire only WARNING When inserting the electric wires, do not connect the conductor to the adjacent wire Before connecting to the power, please inspect and be ensured the wiring is correct DNOTE If there is any difference of each version, please refer to DELTA'S website(http://www.delta.com.tw/industrialautomation/)forthelatest information Revision May, 2018 Table of contents Chapter 1 Installation and Model Explanation .eamma.. ■■■■■■■■■ 1.1 Inspection 1.2 Product model 1-2 1.2.1 Nameplate Information 1-2 1.2.2 Model Explanation 1-3 1.3 Servo Drive and Corresponding Servo Motor 1-5 1.4 Servo drive Features .1-7 1.5 Control modes of servo drive 1-8 Chapter2 nstallation,,,,…,…, 2.1 Notes 2-1 2.2 Ambient Conditions of Storage 2-1 2.3 Ambient conditions of installation 2-2 2. 4 Installation Direction and Space 2-3 2.4.1 Troubleshooting for the motor Operation and status 2-5 2.4.2 Servo Motor Mounting directions and Precautions 25 2.4.3 Precautions for Using Oil Seal Servo Motors ..26 2.4.4 Precautions for Using Couplings…,…,…,…,,………,,2-7 2. 4.5 Oil and Water Prevention measures for the servo motor 2-8 2.4.6 Measures to Suppress Temperature Increase of the Servo Motor... 2-8 2.5 Specification of circuit breaker and Fuse 29 Revision May, 2018 Table of contents ASDA-B2 2.6EmiFilterselectionwwwww.2-10 2.7 Selection of Regenerative Resistor 2-12 Chapter 3 Wiring ■■■■■■■■口■■■■■■■■■■■■■』口■■■■■■■■■■■■■■■■■■■■"■m■n■■■■■■■m■口m■ 3.1 Connections 3.1.1 Connecting to Peripheral devices 3.1.2 Servo Drive Connectors and terminals ................................................3-2 3.1.3 Wiring Method 3.1.4 Specification of Motor Power cable 3-6 3.1.5 Specification of Encoder Connector .3-8 3.1.6 Selection of Wiring rod 3-12 3.2 Basic Wiring ………………………………………3-14 3.2.1 200 W(included)and Models below .3-14 3.2.2400W~750 W Models .3-15 3.2.3 1KW-3 kW Models 3-16 3.3 1/ O Signal(Cn1)Connection 3-17 3.3.1 0 Signal( Cn1)Connector Terminal Layout .3-17 3.3.2 Signals Explanation of connector CN1 3-19 3.3.3 Wiring Diagrams(CN1) 3-27 3.3.4 DI and do Signal Specified by Users 3-34 3.4 CN2 Connector 3-35 3.5 Wiring of CN3 Connector………… 3-37 3.6 Analog monitor output connector -cN5 3-38 Revision May, 20 ASDA-B2 Table of content 3.7 Standard Connection Example……...3-39 3.7.1 Position(PT)Control Mode 3-39 3.7.2 Speed Control Mode................................3-40 3.7.3 Torque Control Mode 3-41 Chapter 4 Panel Display and operation. …44-1 4.1 Panel Description 4-1 4.2 Parameter Setting procedure 4-2 4.3 Status Display 4-3 4.3.1 Save Setting Display 4-3 4.3.2 Decimal point 4-3 4.3.3 Alarm Message∴ 4-3 4.3.4 Positive and Negative Sign Setting 4-4 4.3.5 Monitor Display 4. 4 General function 4-7 4.4.1 Operation of Fault Code Display 4-7 4.42 JOG Mode 4-8 4.4.3 Force DO Output 4-9 4.4.4 Digital Input Diagnosis Operation 4-10 4.4.5 Digital Output Diagnosis Operation 4-10 Chapter5 Trial Operation and Tuning…..….….….…….….…….……….5-1 5. 1 Inspection without Load 5.2 Applying Power to the Servo Drive 5-3 5.3 JoG Trial Run without load 1自自1自面自1重 5-7 Revision May, 2018 Table of contents ASDA-B2 5.4 Trial Run without Load (speed Mode 5-8 5.5 Tuning procedure 5-10 5.5.1 Flowchart of Tuning Procedure ∴5-11 5.5.2 Inertia Estimation Flowchart (with Mechanism) ..5-12 5.53 Flowchart of Auto Tuning……………… 5-13 5.54 Flowchart of Semi-Auto Tuning…… …5-14 5.5.5 Limit of inertia ratio 5-15 5.5.6 Mechanical Resonance Suppression Method 5-17 5.5.7 Tuning Modes and Parameters .5-18 5.5.8 Tuning in Manual Mode 5-19 Chapter 6 Control Modes of operation 6.1 Selection of Operation Mode…… 6-1 6.2 Position mode 6-3 6.2.1 Position command in pt mode 6-3 6.2.2 Control structure of position mode 6-6 6.2.3 Electronic Gear Ratio 6-8 6.2.4 LOw-pass Filter 6-10 6.2.5 Gain Adjustment of Position Loop 6-11 6.3 Speed mode 6-14 6.3. 1 Selection of Speed Mode 14 6.3.2 Control Structure of Speed Mode 6-15 6.3.3 Smoothing Speed Command 6-16 634 The Scaling of Analog Command....……… ∴6-20 vⅢl Revision May, 20 ASDA-B2 Table of content 6.3.5 Timing Diagram in Speed Mode 重1面面自1B道自面面1自首面 6-21 6.3.6 Gain Adjustment of Speed Loop 6-21 6.3.7 Resonance Suppression 6-28 6. 4 Torque Mode 6-36 6.4.1 Selection of Torque Command 6-36 6.4.2 Control Structure of Torque Mode 6-37 6.4.3 Smooth Torque Mode 6-38 6.4.4 The Scaling of Analog Command 6-38 6.4.5 Timing Diagram of Torque Mode .6-40 6.5 Dual modes .6-41 6.5.1 Speed/Position Dual Mode.................... 6-41 6.5.2 Speed /Torque Dual Mode 6-42 6.5.3 Torque/Position Dual Mode 6-42 6.6 Others∴ 6-43 6.6.1 The Use of Speed Limit 6-43 6.6.2 The Use of torque limit 6-43 6.6.3 Analog monitor 6-44 6.6.4 The use of brake 6-49 Chapter 7 Parameters 7-1 7.1 Parameter Definition 7.2 Lists of parameters 日a::日 7-2 7. 3 Parameter Description 7-12 PO-xX Monitor parameters ∴17-12 Revision May, 2018
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: